| Product description | US-09-CO₂-03 is a reliable indoor air quality meter and gas detector, designed not only to monitor carbon dioxide (CO₂) levels, but also to control temperature and humidity. It is especially suitable for use in compressor rooms, where two main problems usually arise: high temperature and low CO₂ levels, which can affect the operation of equipment and the microclimate of the room. Warning levels CO₂ concentration: 1000 ppm (AL1) - the yellow indicator turns on and the relay is triggered, which can start the ventilation system. 1500 ppm (AL2) - the red indicator lights up, the second relay is activated and an audible signal sounds. This is a critical level indicating poor air quality, which can affect the well-being of employees. Temperature: 32 °C (AL1) - signals a deteriorating working environment, warns that additional ventilation or cooling is necessary. 36 °C (AL2) – critical level, ensuring that equipment or personnel are not exposed to harmful heat. Device capabilities Measurement of three parameters simultaneously: CO₂ (400–5000 ppm), temperature (−10 °C to +60 °C), relative humidity (0–90% RH). Two-level warning system – visual (green, yellow, red), audible signals and automatic relay outputs. Automation – relays allow you to connect ventilation, alarm or cooling systems, which are activated at set levels. Reliability – OLED display shows all parameters in real time, the device is designed for continuous operation. Benefits in compressor plants Ensures equipment protection against overheating. Helps maintain a safe environment for workers. Warns of changes in air quality before a critical situation occurs. Automatically activates ventilation or cooling, reducing the need for human intervention. |
| Purpose | ensure the safety and comfort of employees in compressor rooms; protect compressors and other equipment from overheating; automatically control ventilation and cooling systems based on real measurement data; ensure constant monitoring of the microclimate, thus avoiding critical situations. |
| Controlled environment | Carbon dioxide CO2, temperature, relative humidity. |
| Temperature measurement range | (-10...+60)oC |
| Relative humidity measurement range, RH | (0...90) % |
| Sighting range | (400...5000) ppm |
| First emergency level CO₂ | 1000 ppm |
| Second emergency level CO₂ | 1500 ppm |
| First emergency level temperature | 32 °C |
| Second emergency level temperature | 36 °C |
| audible signalling | yes |
| data rendering | yes |
| Light indication | yes |
| relay exit | 10A, 230V AC; 10A,30V DC SPDT |
| Power voltage | 12V, 1A ; DC |
Siekdami užtikrinti geriausią patirtį, naudojame tokias technologijas kaip slapukai, kad išsaugotume ir (arba) gautume prieigą prie įrenginio informacijos. Sutikdami su šiomis technologijomis galėsime apdoroti tokius duomenis kaip naršymo elgsena ar unikalūs ID šioje svetainėje. Nesutikimas arba sutikimo atšaukimas gali turėti neigiamos įtakos tam tikroms funkcijoms ir savybėms.